Capillary columns |
"...for printing this page, please use landscape printing format." |
Capillary guard columns, packed |
Standard capillary columns, packed |
Capillary columns with guard column head and 5 mm guard column, packed |
Capillary columns with 10 mm guard column, packed |
Capillary columns with 20 mm guard column, packed |
Capillary guard columns, packed* |
NovoGROM capillary guard columns for dead-volume-free, finger-tight connection to capillary columns, may be used as enrichment columns or short analytical columns, in addition to the normal use as protective guard columns. |
Order number | Description** | Price (EUR) | |
***.......C0030 | Capillary guard column - 5 mm x 300 µm - | 105,- | |
***.......C0130 |
Capillary guard column - 10 mm x 300 µm - | 105,- | |
***.......C0230 |
Capillary guard column - 20 mm x 300 µm - | 105,- | |
***.......C0050 | Capillary guard column - 5 mm x 500 µm - | 79,- | |
***.......C0150 | Capillary guard column - 10 mm x 500 µm - | 79,- | |
***.......C0250 | Capillary guard column - 20 mm x 500 µm - | 79,- |
Capillary guard column holders (for 5 mm-, 10 mm- and 20 mm guard columns) |
|||
3705A |
Guard column holder 5 for 5 mm capillary guard columns |
1 73.- |
|
3710A | Guard column holder 10 for 10 mm capillary guard columns | 173.- | |
3720A | Guard column holder 20 for 20 mm capillary guard columns | 173.- | |
3705B |
Guard column holder 5 for 5 mm capillary guard columns |
173.- | |
3710B | Guard column holder 10 for 10 mm capillary guard columns | 173.- | |
3720B | Guard column holder 20 for 20 mm capillary guard columns | 173.- |
Quartz glass NovoGROM capillary columns are connected directly (ie., without dead volume) to the microinjector and via fused silica capillary to the capillary HPLC detector cell or to the MS-Interface. | |||
Order number | Description** | Price (EUR) | |
***.......C0508 |
Capillary column - 50 mm x 75 µm - |
455.- |
|
***.......C0808 |
Capillary column - 75 mm x 75 µm - |
455.- |
|
***.......C1008 |
Capillary column - 100 mm x 75 µm - |
455.- |
|
***.......C1508 |
Capillary column - 150 mm x 75 µm - |
481.- |
|
***.......C2508 |
Capillary column - 250 mm x 75 µm - |
506.- |
|
***.......C0510 |
Capillary column - 50 mm x 100 µm - |
455.- |
|
***.......C0810 |
Capillary column - 75 mm x 100 µm - |
455.- |
|
***.......C1010 |
Capillary column - 100 mm x 100 µm - |
455.- |
|
***.......C1510 |
Capillary column - 150 mm x 100 µm - |
481.- |
|
***.......C2510 |
Capillary column - 250 mm x 100 µm - |
506.- |
|
***.......C0520 |
Capillary column - 50 mm x 200 µm - |
455.- |
|
***.......C0820 |
Capillary column - 75 mm x 200 µm - |
455.- |
|
***.......C1020 |
Capillary column - 100 mm x 200 µm - |
455.- |
|
***.......C1520 |
Capillary column - 150 mm x 200 µm - |
481.- |
|
***.......C2520 |
Capillary column - 250 mm x 200 µm - |
506.- |
|
***.......C0530 |
Capillary column - 50 mm x 300 µm - |
455.- |
|
***.......C0830 |
Capillary column - 75 mm x 300 µm - |
455.- |
|
***.......C1030 |
Capillary column - 100 mm x 300 µm - |
455.- |
|
***.......C1530 |
Capillary column - 150 mm x 300 µm - |
481.- |
|
***.......C2530 |
Capillary column - 250 mm x 300 µm - |
506.- |
|
***.......C0550 |
Capillary column - 50 mm x 500 µm - |
455.- |
|
***.......C0850 |
Capillary column - 75 mm x 500 µm - |
455.- |
|
***.......C1050 |
Capillary column - 100 mm x 500 µm - |
455.- |
|
***.......C1550 |
Capillary column - 150 mm x 500 µm - |
481.- |
|
***.......C2550 |
Capillary column - 250 mm x 500 µm - |
506.- |
|
***.......C0580 |
Capillary column - 50 mm x 800 µm - |
455.- |
|
***.......C0880 |
Capillary column - 75 mm x 800 µm - |
455.- |
|
***.......C1080 |
Capillary column - 100 mm x 800 µm - |
455.- |
|
***.......C1580 |
Capillary column - 150 mm x 800 µm - |
481.- |
|
***.......C2580 |
Capillary column - 250 mm x 800 µm - |
506.- |
|
Capillary columns with guard column head and 5 mm guard column, packed* |
NovoGROM capillary guard columns are connected directly without dead volume to the NovoGROM capillary columns by means of the column head. |
Order number |
Description ** |
Price (EUR) |
|
***.......C0530T |
Capillary column - 50 mm x 300 µm - with 5 mm x 300 µm guard column |
660.- |
|
***.......C0830T |
Capillary column - 75 mm x 300 µm - with 5 mm x 300 µm guard column |
660.- |
|
***.......C1030T |
Capillary column - 100 mm x 300 µm - with 5 mm x 300 µm guard column |
660.- |
|
***.......C1530T |
Capillary column - 150 mm x 300 µm - with 5 mm x 300 µm guard column |
685.- |
|
***.......C2530T |
Capillary column - 250 mm x 300 µm - with 5 mm x 300 µm guard column |
711.- |
|
***.......C0550T |
Capillary column - 50 mm x 500 µm - with 5 mm x 500 µm guard column |
660.- |
|
***.......C0850T |
Capillary column - 75 mm x 500 µm - with 5 mm x 500 µm guard column |
660.- |
|
***.......C1050T |
Capillary column - 100 mm x 500 µm - with 5 mm x 500 µm guard column |
660.- |
|
***.......C1550T |
Capillary column - 150 mm x 500 µm - with 5 mm x 500 µm guard column |
685.- |
|
***.......C2550T |
Capillary column - 250 mm x 500 µm - with 5 mm x 500 µm guard column |
711.- |
|
***.......C0580T |
Capillary column - 50 mm x 800 µm - with 5 mm x 800 µm guard column |
660.- |
|
***.......C0880T |
Capillary column - 75 mm x 800 µm - with 5 mm x 800 µm guard column |
660.- |
|
***.......C1080T |
Capillary column - 100 mm x 800 µm - with 5 mm x 800 µm guard column |
660.- |
|
***.......C1580T |
Capillary column - 150 mm x 800 µm - with 5 mm x 800 µm guard column |
685.- |
|
***.......C2580T |
Capillary column - 250 mm x 800 µm - with 5 mm x 800 µm guard column |
711.- |
|
* NovoGROM capillary columns can be packed with any of the stationary phases listed on these web sites, resp. in GROMs HPLC 2000 catalogue or with the customers stationary phase. |
** Other dimensions upon request. |
*** To complete the order number, add here the abbreviation for the desired stationary phase (see GROMs HPLC catalogue pages 160 161). |